Medium-Voltage Switching
MV Disconnectors & Insulators
Visible isolation, safe maintenance
Disconnectors switch a de-energised circuit in medium- and high-voltage systems, giving maintenance staff a visible isolation point. The disconnectors we supply comply with TS EN 62271-102 and come from ISO 9001 quality-assured production. They are available in indoor and outdoor types, with Normal, Earthed, Fused and Fused-Earthed functions.
Product Families
Outdoor MV Disconnectors
Pole-top / open switchyard; porcelain or silicone insulator; 630–1250 A.
Indoor Disconnectors
Indoor and kiosk; porcelain or epoxy insulator; DN/DT/DS/DST.
Load-Break Switches
Arc-quenched on-load switching; single/three-pole; porcelain/epoxy/silicone.
Silicone Insulators
Hydrophobic, light, UV-resistant; VHD 35, K1 (40 kN), K2 (100 kN), post/drive.
Disconnector Spare Parts
24-48-110 VDC motor drives, contacts, blades, earth blade, fuse holder.
Key Technical Values
- Rated Voltage
- 36 kV
- Withstand Current
- 16 kA
- Rated Current
- 630 A / 1250 A
- Function Types
- Normal · Topraklı · Sigortalı · Sig.-Topraklı
- Insulator Options
- Porselen · Epoksi · Silikon
- Operating Mechanism
- Manuel veya 24/48/110 VDC motorlu
Application Areas
- Pole-top isolation points on distribution networks
- Substation incoming isolation
- Kiosk and indoor MV equipment
- Overhead-line to transformer transitions (fused)
- Sectional isolation in ring networks
Why Powals?
Full Function Range
Normal, earthed, fused and fused-earthed; 630 A and 1250 A from a single source.
Insulator Flexibility
Porcelain, epoxy or silicone to suit site pollution class and climate.
SCADA-Ready
Ready for remote operation with motor drives and auxiliary contacts.
Reference Standards
Certificates and test reports belong to the supplied products and their manufacturers; shared with the quotation file.
Frequently Asked Questions
What is the difference between an MV disconnector and a circuit breaker?+
A disconnector provides a visible isolation gap for safe maintenance but does not interrupt load current, whereas a circuit breaker interrupts load and fault currents. The two operate in coordination.
MV Disconnectors & Insulators
Send us your requirement list and mounting type; we will prepare the right function-insulator combination and a quotation.
Other Product Families
Power & Distribution
Transformers
Reliable transformation at the heart of energy
ExplorePower & Distribution
Metal Kiosk Substations
Your substation arrives factory-built, energise it on site
ExplorePower & Distribution
E-House
Don't build your electrical room — take delivery of it
Explore